Reference state: two property tables, one hidden offset

Subtract two states inside one table and the reference point cancels. Mix two tables and it does not. Check whether your sources differ by a constant before you trust a difference.

Live result

The two changes are 40000.000 and 40000.000 J/kg. A constant offset cancels.
The two changes are 40000.000 and 40000.000 J/kg. A constant offset cancels.

Two sources across two states

Live chart
Two sources across two statesSource A runs from 100000.000 to 140000.000 and Source B from 400000.000 to 440000.000, both in J/kg. The offset is 300000.000 at the first state and 300000.000 at the second, so the offset drift is 0.000.100,000270k440kJ/kgState 1State 2Source ASource BOffset 1 · 300kOffset 2 · 300kOffset drift · 0.000Offset 1 · 300kOffset 2 · 300kOffset drift · 0.000

Try a record

50kJ/kg

Slide it and the two changes hold while both offsets move together.

Edit the two property records▾
▾
Source A
▾
Source B
▾

Constant offset sensitivity

Shifted Source B record

The reported changes stay fixed when the same constant is added to both Source B states.

Entered record

40000.000 J/kg

Shifted Source B record

40000.000 J/kg

Authoritative result table

State 1 value
Source A
100000.000
Source B
400000.000
Difference
300000.000
State 2 value
Source A
140000.000
Source B
440000.000
Difference
300000.000
Change from state 1 to state 2
Source A
40000.000
Source B
40000.000
Difference
0.000
Offset at state 1
300000.000
Offset at state 2
300000.000
Offset drift residual
0.000
Authoritative result table
MeasureSource ASource BDifference
State 1 value100000.000400000.000300000.000
State 2 value140000.000440000.000300000.000
Change from state 1 to state 240000.00040000.0000.000
Offset at state 1
300000.000
Offset at state 2
300000.000
Offset drift residual
0.000

Equation trace, boundary, sources, and version

▾

Equation trace

  1. Convert both sources to the canonical unit.
  2. Subtract state 1 from state 2 within Source A.
  3. Subtract state 1 from state 2 within Source B.
  4. Calculate the Source B minus Source A offset at each state.
  5. Subtract the two offsets and reconcile that result with the difference between the two changes.
ΔA=A2−A1\Delta A=A_2-A_1ΔA=A2​−A1​
where ΔA\Delta AΔA is the Source A change, A2A_2A2​ its second state, and A1A_1A1​ its first state.
ΔB=B2−B1\Delta B=B_2-B_1ΔB=B2​−B1​
where ΔB\Delta BΔB is the Source B change, B2B_2B2​ its second state, and B1B_1B1​ its first state.
d1=B1−A1d2=B2−A2d_1=B_1-A_1\qquad d_2=B_2-A_2d1​=B1​−A1​d2​=B2​−A2​d1=B1−A1d2=B2−A2\begin{gathered}d_1=B_1-A_1 \\ d_2=B_2-A_2\end{gathered}d1​=B1​−A1​d2​=B2​−A2​​
where d1d_1d1​ is the first state offset and d2d_2d2​ the second state offset.
d2−d1=ΔB−ΔAd_2-d_1=\Delta B-\Delta Ad2​−d1​=ΔB−ΔA

Boundary

This comparison is valid only for the same property at the same two physical states and on compatible bases, and it does not reconcile different phases, compositions or state definitions.

Source anchors

  • NIST REFPROP documentation. Describes property conventions and reference state handling in the software documentation.
  • NIST REFPROP user guide. Provides the published guide for selecting and interpreting reference states.

Calculation version

1.0.0

The whole record prints. Your browser can save it as a PDF instead of printing it.

This page compares entered property values. It does not establish that the two sources describe identical physical states.

Related

  • General material balance: five terms, and the zeros are the assumptionsA vessel runs steady and another fills slowly. One balance describes both, and it has five terms: input, generation, output, consumption, accumulation. Most working arithmetic writes three of them as zero and never says why. The zeros are the model. Name what each zero claims and the ledger closes on a residual you can read instead of a number you have to trust.
  • Recycle and purge: the boundary never sees what the equipment carriesFresh feed goes in at 120 kmol an hour and product and purge come out at 120, so the plant balance closes on the figure it opened with. The reactor inlet reads 444. Recycle never crosses the outer boundary, so no overall balance can show it, and the purge fraction that stops the inert piling up is the same figure that sets how hard the loop circulates. Type four numbers and the whole loop solves in one pass, with no separator to configure and nothing looked up.

Reference state cancellation record

Reference state: two property tables, one hidden offset

Accepted inputs

Property
Enthalpy
Source A State 1
100 kJ/kg
Source A State 2
140 kJ/kg
Source B State 1
350 kJ/kg
Source B State 2
390 kJ/kg
Constant added to both Source B states
50

Authoritative results

Source A Change from state 1 to state 2
40000.000 J/kg
Source B Change from state 1 to state 2
40000.000 J/kg
Offset at state 1
300000.000 J/kg
Offset at state 2
300000.000 J/kg
Offset drift residual
0.000 J/kg
Constant offset sensitivity
The reported changes stay fixed when the same constant is added to both Source B states.

Record fields

Calculation version
1.0.0
Boundary
This comparison is valid only for the same property at the same two physical states and on compatible bases, and it does not reconcile different phases, compositions or state definitions.
Ordered calculation trace
Convert both sources to the canonical unit. Subtract state 1 from state 2 within Source A. Subtract state 1 from state 2 within Source B. Calculate the Source B minus Source A offset at each state. Subtract the two offsets and reconcile that result with the difference between the two changes.
Source anchors
NIST REFPROP documentation; NIST REFPROP user guide

This page compares entered property values. It does not establish that the two sources describe identical physical states.

Calculation version: 1.0.0

Badr Alghamdi · badralghamdi.com/tools/reference-state-cancellation