Lumped capacitance: after ten hours one packing is still under its limit

Type the yard temperature hour by hour and each packing's limit. After 10 hours the lighter option reads 10.5 degrees and the heavier 6.6, so one is still inside.

Live result

At 10 hours, 1 of the options are still at or below their typed limit. Heavy pack
  • options compared2
  • next checked change15 hours
At that checked dwell, the set of options still within their limits changes.
At 10 hours, 1 of the options are still at or below their typed limit. Heavy packAt that checked dwell, the set of options still within their limits changes.

Temperature trace and checked dwell

Live chart
Typed option temperatures across unpowered yard dwellAt 2 typed options, 1 remain at or below their own limits. The checked dwell is shown against every option trace and the typed ambient log.-1.410.221.833.40306090120Temperature, typed degree scaleUnpowered dwell, hoursYard ambient12Current dwell
  1. 1. Light pack10.5 degrees
  2. 2. Heavy pack6.6 degrees
Live chart
Signature across checked dwell valuesThe rail checks 25 dwell values from 0 to 120 hours and marks the current signature and each first outside hour.Light pack, Heavy pack2Heavy pack1None0120306090120Unpowered dwell, hours

Try a scenario

Typed yard case

10hours

This is the one control tracked across the chart and sweep rail.

▾

Use a whole number that divides 120 and places the dwell on the grid.

Packing options

2 / 5

Option 1

degrees
degrees
kJ/K
W/K

Option 2

degrees
degrees
kJ/K
W/K

Yard ambient log

1 / 121

Ambient row 1

hours
degrees

Tracked answer

Light pack

End reading
10.5 degrees
Typed limit
8 degrees
State
Above

Heavy pack

End reading
6.6 degrees
Typed limit
8 degrees
State
At or below
OptionEnd readingTyped limitState
Light pack10.5 degrees8 degreesAbove
Heavy pack6.6 degrees8 degreesAt or below

First checked crossings

Light pack
10 hours
Heavy pack
15 hours
First change above
15 hours
First change below
5 hours

The boundary is the typed lumped body, ambient log, and limits. Stratification, openings, sunlight, sensor position, phase change, and events outside the typed window are not represented.

Here is the maths

▾

The formula, in words

For each constant ambient segment, multiply the gap from ambient by exp of minus conductance rate times elapsed hours, then add ambient. Conductance rate equals 3.6 times effective conductance divided by heat capacity.

T=Ta+(T0−Ta)exp⁡(−kt)T = T_a + (T_0 - T_a)\exp(-kt)T=Ta​+(T0​−Ta​)exp(−kt)

where TTT is the reading at the end of the segment, TaT_aTa​ the ambient temperature, T0T_0T0​ the reading at its start, kkk the conductance rate an hour, and ttt the elapsed hours.

A worked example

Both options start at 2 degrees in a yard at 30 degrees, with a typed limit of 8 and effective conductance of 10 W/K.

For the light option, kkk equals 3.6 times 10 divided by 1,000, or 0.036 per hour. After 10 hours its reading is 10.5 degrees.

For the heavy option, kkk equals 0.018 per hour. After 10 hours its reading is 6.6 degrees, so only the heavy option remains inside.

What this does not model

The model treats each option as one temperature. It does not represent stratification, openings, direct sun, sensor position, phase change, or an untyped event.

Check it yourself

At zero dwell, each option equals its typed starting temperature. With zero conductance, its reading stays there through the full sweep.

Sources

  • Published lumped capacitance heat transfer mathematics.
  • Cold chain guidance on recording temperature excursions, described here without qualification tables or product limits.

Model version

1.0.0

The whole record prints. Your browser can save it as a PDF instead of printing it.

Every limit and temperature log shown here comes from your entries. This calculation qualifies no load, validates no packing, supplies no product or carrier limit, and is not a temperature record.

Related

  • Intermediate maximum: the yard peaks before clearance endsCleared boxes arrive in the yard faster than trucks take them away, so the pile peaks while clearance is still running. The height of that peak and the day it lands both move with one rate.
  • Container utilisation: will it fit, and what runs out firstCartons into a container, and which limit bites first. A load can run out of payload with a third of the space still empty, and on pallets a third limit arrives: the length budget the columns have to fit inside.

Unpowered yard temperature record

Lumped capacitance: after ten hours one packing is still under its limit

Accepted inputs

Unpowered yard dwell
10 hours
Sweep step
5 hours
Option 1 Option label
Light pack
Option 1 Starting temperature
2 degrees
Option 1 Typed limit
8 degrees
Option 1 Heat capacity
1,000 kJ/K
Option 1 Effective conductance
10 W/K
Option 2 Option label
Heavy pack
Option 2 Starting temperature
2 degrees
Option 2 Typed limit
8 degrees
Option 2 Heat capacity
2,000 kJ/K
Option 2 Effective conductance
10 W/K
Ambient row 1
0 hours, 30 degrees

Computed readings

Tracked answer
1 / 2
Light pack
10.5 degrees, Above
Heavy pack
6.6 degrees, At or below
First outside Light pack
10 hours
First outside Heavy pack
15 hours
First change above
15 hours
First change below
5 hours

Record fields

Model version
1.0.0
Boundary
The boundary is the typed lumped body, ambient log, and limits. Stratification, openings, sunlight, sensor position, phase change, and events outside the typed window are not represented.
Source basis
Published lumped capacitance heat transfer mathematics. Cold chain guidance on recording temperature excursions, described here without qualification tables or product limits.

Every limit and temperature log shown here comes from your entries. This calculation qualifies no load, validates no packing, supplies no product or carrier limit, and is not a temperature record.

Badr Alghamdi · badralghamdi.com/tools/hours-with-the-power-off