Unpowered yard temperature record
Lumped capacitance: after ten hours one packing is still under its limit
Accepted inputs
- Unpowered yard dwell
- 10 hours
- Sweep step
- 5 hours
- Option 1 Option label
- Light pack
- Option 1 Starting temperature
- 2 degrees
- Option 1 Typed limit
- 8 degrees
- Option 1 Heat capacity
- 1,000 kJ/K
- Option 1 Effective conductance
- 10 W/K
- Option 2 Option label
- Heavy pack
- Option 2 Starting temperature
- 2 degrees
- Option 2 Typed limit
- 8 degrees
- Option 2 Heat capacity
- 2,000 kJ/K
- Option 2 Effective conductance
- 10 W/K
- Ambient row 1
- 0 hours, 30 degrees
Computed readings
- Tracked answer
- 1 / 2
- Light pack
- 10.5 degrees, Above
- Heavy pack
- 6.6 degrees, At or below
- First outside Light pack
- 10 hours
- First outside Heavy pack
- 15 hours
- First change above
- 15 hours
- First change below
- 5 hours
Record fields
- Model version
- 1.0.0
- Boundary
- The boundary is the typed lumped body, ambient log, and limits. Stratification, openings, sunlight, sensor position, phase change, and events outside the typed window are not represented.
- Source basis
- Published lumped capacitance heat transfer mathematics. Cold chain guidance on recording temperature excursions, described here without qualification tables or product limits.